Power Search

Share Facebook Share Twitter Share Pinterest Share Email

PILOT ODS ASSEMBLY PROPANE J3866

104286-01
Model: 104286-01
 
PILOT ODS ASSEMBLY PROPANE J3866
39.60 /EACH
 
Stock: Available
 
Weight: 6.00
Order placed for this item will typically take 7-10 business days to arrive

Manufacturer: DESA PRODUCTS


The 104286-01 Liquid Propane Gas Pilot ODS Assembly is also sold as PP224 Pilot ODS and LPG8420 Pilot ODS. This is an OEM replacement part and is rated for 2500 hours of operation.

This 104286-01 / PP224 / LPG8420 Pilot ODS was used in many of the Vanguard, Comfort Glow, Desa, FMI, Legacy RMC series, Design Dynamic and other fireplaces and gas logs from many different manufactures.

This is the 104286-01 Pilot ODS assembly used to control the gas control valve on many of the devices used today in direct vents and vent free fireplaces, gas logs, zone heaters, wall heaters and other appliances.

The 104286-01 is used in zone heating, decorative heating and other types of heating using gas fired appliances and devices that require a constant pilot with an oxygen depletion system and thermocouple shut off system.

The 104286-01 LPG8420 lpg 8420 Pilot ODS Oxygen Depletion Sensor (ODS) assembly with integrated thermocouple is specifically designed for appliances burning LPG Gas / Propane including Un-vented Vent-Free fireplaces, gas logs, stoves, heaters and other similar appliances.

The 104286-01 LPG8420 LPG 8420 Pilot ODS Oxyprotector parts are all integrated to provide long life and guaranteed performance.

Single long life thermocouple wire.

LPG8420 Pilot ODS with integrated thermocouple

Quick and easy assembly on gas appliance.

Protected flame inside the pilot burner to help protect against influences by air currents.

Complies with current European and CSA Norms.

The 104286-01 is currently used by several manufactures including:
Desa Intenational, Empire Products, World Marketing, Fireplace Manufacture Inc, FMI, Mr Heater, Enerco Products, Pinnacle Products, Pro-Com Design Dynamics and other manufactures.



The 104286-01 Pilot ODS Oxygen Depletion Sensor (ODS) assembly with integrated thermocouple will fit the following list of appliances made by several manufactures including but not limited to Desa International products, Vanguard Fireplaces and Gas logs, Mr Heater, Enerco, Comfort Glow fireplaces, gas logs and pedestal stoves, Empire gas burning logs and fireplaces, FMI Design Dynamics, Magic Heat, Pro Com heater by Pinnacle Products and Sure Heat products.

The following is just a partial list of many of the propane gas appliances the 102486-01 Pilot ODS assembly will fit.

Fits: DESA Heating Products Unvented (Vent-Free) Propane LP Gas Log Heater Models:
CDR3924PT
CDR3924PT LLT
CGX3924PT
CGX3930PT
CSG3924PT
CSG3930PT
CTB3924PT
CTB3930PT
H18P
H24P
LDL3924PT

Fits Legacy Unvented Gas Fired Room Heater Model:
RMC-LI10LP
RMC-LI10LPT
RMC-LI18LP
RMC-LI18LPT
RMC-LI30LP
RMC-LI30LPT
RMC-LC10LP
RMC-LC20LP
RMC-LC30LP

Fits: Comfort Glow Unvented (Vent-Free) Propane LPG Gas Log Heater Models including Vanguard:
CCL3018P
CCL3018PA
CCL3018PA LLT
CCL3018PT
CCL3018PTA LLT
CCL3924PA
CCL3924PA LLT
CCL3924PT
CCL3924PTA
CCL3924PTA LLT
CCL3930PT
CCL3930PTA
CCL3930PTB
CGB3924PT
CGB3930PT
CGD3018P
CGD3018PT
CGD3924P
CGD3924PT
CGD3930P
CGD3030PT
CRL2718P
CRL2718PA
CRL2718PA LLT
CRL3124P
CRL3124PA
CRL3124PA LLT

Fits: DESA Heating Products Unvented (Vent-Free) Propane LPG Gas Log Heater under the Meadowbrook Oak Log Design Models:
CDL3924PT

Fits: Comfort Glow Unvented (Vent-Free) Propane LPG Bay Front Fireplace Models:
CF26PT
CF26PTA
CF26PTA LLT
NMCF26PT

Fits: DESA Hearth Products Vent- Free Propane LP Gas Compact Fireplace Models:
CGCFTP
CGCFTP LLT
LGCFTP

Fits: DESA Heating Products Vent- Free Propane LPG Compact Classic Hearth Fireplace Models:
EFS10TP
EFS10TPA
EFS10TPA LLT
FMH26TP
VMH10TPB
FMH26TP

Fits Home Depot DESA Heating Products Vent- Free Propane LPG Compact Classic Hearth Fireplace Models: HDCFTP
HDCFTPA
HDCFTP LLT
HDVF3018P

Fits: DESA Heating Products Royal Oak Unvented (Vent- Free) Propane LPG Gas Log Heater Models: CGS2718P
CGS2718PA
CGS2718PA LTT
CGS3124P
CGS3124PA
CGS3124PA LLT

Fits: DESA Heating Products Winchester Oak Unvented (Vent- Free) Propane LPG Gas Log Heater Models: CLD3018P
CLD3018PA
CLD3018PT
CLD3018PTA
CLD3018PTA LTT
CDL3924PT
CLD3924PTA
CLD3924PTB
CLD3924PTB
SGS3124P

Fits: Comfort Glow Unvented (Vent-Free) Propane LPG Gas Pedestal Stove Heater Models:
CSBPT
CSBPT LTT
CSPBPT
CSPIPT
CS26PT
SL30PT

Fits: DESA Heating Products Royal English Oak Unvented (Vent- Free) Propane LPG Gas Log Heater Models: CSL2718P
CSL2718P LLT

Fits: Comfort Glow Mountain Oak Unvented (Vent-Free) Propane LPG Gas Log Heater Models:
CY2718P
CY3124P

Fits: Comfort Glow Premium Aged Split Oak Unvented (Vent-Free) Propane LPG Gas Log Heater Models: CGB3924PT
CGB3930PT

Fits DESA Hearth Products Unvented (Vent-Free) Propane LPG Fireplace Models:
L32HP
VL32HP
L32LHP
VL32LHP

Fits: Comfort Glow Yellow Flame Unvented (Vent-Free) Propane LPG Gas Log Heater Models:
CGD3018P
CGD3924P
CGD3930P

Fits: Comfort Glow Vent-Free Propane LPG Gas Freestanding Pedestal Stove System Model:
CFS26PT
S26PTA
S26PTA LLT

Fits: Vanguard Vent- Free Propane LPG Compact Classic Hearth Fireplace Models:
FSVYD18P

Fits (FMI) Fireplace Manufacturers Incorporated Unvented (Vent-Free) Propane LPG Gas Log Heater Model: Heat Magic FVF18P
Heat Magic FVF24P
Heat Magic FVF30P

Fits: DESA International Unvented (Vent-Free) Propane LPG Gas Stove Heater Models:
SVYD18P
FSYD18P

Fits: DESA International Unvented (Vent-Free) Propane LPG Gas Log Heater Model:
LX3924PT

Fits: DESA Heating Products Unvented (Vent- Free) Propane LPG Gas Log Heater Echo Valley Oak Log Design Model:
LSL2718P
LSL3124P

Fits: DESA Heating Products Unvented (Vent- Free) Propane LPG Gas Log Heater Meadowbrook Oak Log Design Model:
CDL3924PT

Fits Sun Valley Stove Company Unvented (Vent-Free) Propane LPG Gas Stove heater Model:
MSVFBP

Cross Reference: 104286-01, PP224. LPG8421, LPG8418, LPG8417, LPG8402
Service Information:

General Instructions for Replacing ODS/Pilot Assembly

Annual Replacement Recommended

WARNING

Only a state licensed or qualified service technician should service and repair appliance.
Turn off gas and electric to appliance and let cool before servicing.
Never service an appliance while the unit is still in operation or still hot.
Never service any appliance, fireplace or heater that is plugged in to any electrical source.
Always test appliance, fireplace or heater for gas leaks after repair.
Follow instructions to help prevent risk of electrical shock or severe burns.

These are general instruction and all heaters may not require the same steps or have the same components as indicated in these instructions.

  1. Turn heater off and let cool for at least 30 minutes before beginning to replace the Pilot.
    • If so equipped, make sure the selector switch is in the OFF position.
    • Also turn off the main gas line to the appliance.
    • Carefully remove the front panel or glass from the heater. **
    • Carefully remove the log assembly and place in a safe location until servicing is completed. **
  2. Locate the pilot using the illustrated parts list of the Owners Manual.
    • It may be necessary to remove the heater assembly from the firebox on some models. **
  3. Using two 7/16 wrenches loosen the connection between the pilot tube and the pilot.Warning: If there is not a second wrench FLAT location provided on the ODS/Pilot tube extra care must be taken to not over torque the nut and damage the pilot tube.
  4. Remove the igniter cable from the pilot.
  5. Using a 5/16 wrench, remove the thermocouple wire from the gas control valve.Note: Some ODS/Pilot assemblies will have a thermopile pre-installed in bracket.
    Please follow the instruction below for Thermopile wire removal and replacement.**
    • Remove the White wire from the TP TH; terminal of the gas control valve.
    • Remove the Red wire from the TH; terminal of the gas control valve.
      • Always make a note of wire color and positions before removal.
  6. Remove and retain (for re-assembly) the fasteners that hold the pilot to the pilot bracket. These fasteners will either be screws or nuts.
    • These fasteners and any additional parts (shields) will need to be used during reassembly.
  7. Now remove the pilot from the heater assembly.
  8. Install the new pilot assembly exactly as the original using the original fasteners and any additional pieces such as shielding that may have been present and removed during the disassembly process.
  9. Thread thermocouple wire to the valve and tighten the connector to 1/4; turn past finger tight. Care must be taken to not over tighten this fitting because it may damage the connector.
  10. Using the same two 7/16 wrenches carefully reconnect the connection between the pilot tube and the pilot.Warning: If there is not a second wrench FLAT location provided on the ODS/Pilot tube extra care must be taken to not over torque the nut and damage the pilot tube.
    Note: Some ODS/Pilot assemblies will have a thermopile pre-installed in bracket.
    Please follow the instruction below for Thermopile wire removal and replacement.**
    • Connect the White wire to the TP TH terminal of the gas control valve.
    • Connect the Red wire to the TH terminal of the gas control valve.
      • If wire color or position was different connect per notes taken.**
  11. Connect the igniter cable to the electrode.
  12. If your appliance was removed from the gas supply you must now reconnect the gas supply to your appliance and test for any leaks using an approved gas leak detection solution.
    • Please consult your Owners Manual or local codes for approved solutions. **
  13. Complete the installation by following the installation instructions in the owners manual.

    For further help and instructions please contact our office at 1-877-475-5660 or email us at customerservice@allpartsinc.com

    You
    may also choose to visit the support forum at: http://desatech.desaparts.com